Timer relay with delay timer 32 modes 12V
![Cyfrowy przekaźnik czasowy 6-30V Cyfrowy przekaźnik czasowy 6-30V](https://abc-rc.pl/data/gfx/pictures/large/0/1/19910_3.jpg?68981)
Reliable tool for precise time control
Delay timer relay with timer delay 32 modes is a reliable tool that allows precise time control in various applications. With a wide range of operating modes, the user can adjust the delay to meet specific requirements.
Application in various fields
This relay can be used in industrial automation, security systems, HVAC systems, monitoring systems and many others. The use of time delays makes it possible to optimize equipment operation, automate processes and increase efficiency.
Precision, reliability and durability
The 32-mode delay timer relay provides not only precision, but also reliability and durability, making it an invaluable tool for professionals and advanced hobbyists in the field of electronics and automation.
The module has a control relay at its output, which, depending on the operating state, opens or closes its contacts, thus controlling any working circuit, which can be roughly compared to the operation of an ordinary ON/OFF switch.
Relay does not output voltage.
Technical data:
- supply voltage: 12V
- 32 modes of operation
- memory of settings in case of power failure
- operation in a loop and as a delay
- triggering operation by low state, high state and application of power to the module
- relay supports 14VDC and 20A and 125VAC and 20A AC
- dimensions: 65mm x 40mm
Description of the module's outputs:
- OUT+, OUT- - output
- 6 - 30V - plus module power supply
- GND - power supply ground of the module
- Trigger- relay trigger input
- GND_T - ground of the relay trigger input
By holding down the K1 button longer, you enter the mode selection menu.
In the modes menu, use the K2, K3, K4 buttons to set the mode number from which we will be
use Our choice we approve K1.
Depending on the selected mode, we may have to set:
A - time 1
B - time 2
C - number of repetitions
For A and B can be set, different units of time.
Time units:
X.XX - set in the range of 0.01 to 9.99 seconds
XX.X. - set in the range of 0.1 to 99.9 seconds
XXX - set in the range of 1 to 999 seconds
XXX. - set in the range of 1 to 999 minutes
XX.X. - set in the range of 1 to 999 hours
Adjust the value by pressing or holding (faster change):
K2 button up
K3 button down
Additional features:
- The display backlight can be turned on and off using the K4 button if you are in the
on the home screen.
- Countdown reset can be performed by holding down the K1 button
LIST OF MODES:
(trigger - we call the application of voltage to the IN+ and IN- ports, using the diagram in the
instructions can be interpreted as pressing a button)
- P - 11: relay changes state as long as trigger is pressed.
- P - 12: the relay changes to the opposite state every time the trigger is pressed,
- P - 13: when the trigger is pressed, the relay is switched on for time A, during the countdown trigger inactive
- P - 14: when the trigger is pressed, the relay is switched on for time A, pressing the trigger counts down again, holding the trigger does nothing
- P - 15: when the trigger is pressed, the relay is switched on for time A, each subsequent press of the trigger adds time A, holding the trigger does nothing. By setting A to 5 seconds, pressing the trigger 4 times during the countdown will increase the time to countdown by 2 seconds.
- P - 16: when the trigger is pressed, the relay is switched on for time A, pressing the trigger again stops the operation and resets the counter.
- P - 17: the program starts counting down only after releasing the trigger, holding the trigger during the countdown stops the countdown and resets the timer, releasing makes the time count down from the beginning.
- P - 18: the module counts down time A when power is applied. Trigger inactive.
- P - 21: When the trigger is pressed, the delay time A is counted down and the relay is switched on permanently.
- P - 22: Set time A, holding the trigger longer than the set time A turns on the relay, the relay turns off immediately after releasing the trigger.
- P - 23: Holding the trigger causes the module to not respond, releasing the trigger causes the time delay A to count down and the relay to turn on. Holding the trigger again while the relay was on - disables the relay.
- P - 24: Holding the trigger for time A turns on the relay, when the relay is turned on the module counts down time A until the relay is turned off, the countdown is reset and stopped when the trigger is pressed or held.
- P - 25: Holding the trigger for time A turns the relay on, holding the trigger again for time A turns the relay off.
- P - 26: By holding the trigger the module closes the relay and starts counting down time A, if the countdown is completed and after that the trigger is released the relay closes again and counts down time A
- P - 27: The module at the ascending or descending see signal counts down time A and the relay is open. If the signal disappears after the countdown of time A, the relay is switched on and remains so until the signal is given again.
- P - 28: When the power is applied, the module counts down the delay time A and turns on the relay, which remains on until the power fails. Trigger inactive.
- P - 31: When power is applied, the module turns the relay on for time A, then turns the relay off for time B. Everything happens in an endless cycle.
- P - 32: The program runs only while holding the trigger. Relay turns on for time A and turns off for time B.
- P - 33: Program starts and stops with a single press of the trigger. Relay turns on for time A and off for time B in an infinite loop.
- P - 34: When power is applied, the relay counts down time A then turns the relay on, then counts down time B and turns it off. The program is executed only once. Trigger inactive.
- P - 35: Pressing the trigger counts down the delay time A then activates the relay for time B. During countdown trigger inactive.
- P - 36: The program only executes while holding the trigger until it is released. The module counts down time A, then turns on the relay for time B.
- P - 37: When the trigger is pressed, the relay turns on for time A, turns off for time B in turn. During countdown trigger inactive.
- P - 38: When the trigger is pressed, the relay turns on for time A, turns off for time B, and turns on again for time A. During countdown trigger inactive.
- P - 41: When the trigger is pressed, the module turns on the relay and starts timing A. Holding the trigger stops the count, releasing the trigger restarts the countdown.
- P - 42: Pressing and releasing the trigger starts the countdown of delay time A, then the relay is switched on for time B. Holding the trigger stops the countdown but does not reset the counter.
- P - 43: After pressing the trigger, the module counts down the delay time A, every time you hold the trigger during the countdown A stops the countdown and resets the timer, if the time A elapses the relay switches on for the time B. Holding the trigger during countdown B stops the counter but does not reset it.
- P - 44: When power is applied, the relay is switched on for time A, switched off for time B. The program repeats the set number of cycles C. Trigger inactive.
- P - 45: When the trigger is pressed, the relay is switched on for time A, switched off for time B. The program repeats the set number of cycles C. Trigger inactive during countdown.
- P - 46: Set the number of trigger presses in A. Now each press of the trigger increases the counter by 1. If the counter reaches A the relay will turn on and stay that way until the power supply is reset.
- P - 47: Set the number of trigger presses in A. Now each press of the trigger increases the counter by 1. If the counter reaches A, the relay will turn on for the time set in B.
- P - 48: Set the number of trigger presses in A. In B, set the relay switching time. In C, set the time counted between successive triggers presses. If pressing A does not occur after the time set in C, the press counter resets. If the counter reaches the value set in A the relay starts for the time set in B